国产精品久久久久免费视频_天天综合网天天综合色不卡_国产精品一区久久久_色爱区综合激月婷婷激情五月_免费在线观看a级片_免费无码AV色情在线

Conveyor switch

JLK3-S for MHP-S rope switch power plant steel plant

The MHP-S rope switch used in the steel plant of the power plant is installed on the frames on both sides of the belt conveyor, and the switch is connected along both sides of the conveyor with steel wire ropes. When an emergency occurs in the conveyor belt equipment, the steel wire rope is pulled at any location along the site, and the steel wire rope drives the drive arm to rotate. The precision cam is displaced by the torque spring driven by the transmission shaft, and the micro switch is driven to cut off the control line, causing the conveyor to stop running.

  • MHP-S rope switch used in steel plants of power plants
  • ZHUOXIN
  • 24-380v
  • IP65
  • TT, Paypal, Credit card, Western union
  • +86-15163766288
  • The MHP-S rope switch used in the steel plant of the power plant is installed on the frames on both sides of the belt conveyor, and the switch is connected along both sides of the conveyor with steel wire ropes. When an emergency occurs in the conveyor belt equipment, the steel wire rope is pulled at any location along the site, and the steel wire rope drives the drive arm to rotate. The precision cam is displaced by the torque spring driven by the transmission shaft, and the micro switch is driven to cut off the control line, causing the conveyor to stop running.

Description

Conveyor switch

The MHP-S rope switch used in power plant steel plants is composed of a pull rod, a reset handle, a cam, a locking groove, and a micro switch. The pull rope switch is installed on the frames on both sides of the belt conveyor, and is connected along both sides of the conveyor with a steel wire rope. When an emergency occurs in the conveyor belt equipment, the steel wire rope is pulled at any location along the site, and the steel wire rope drives the drive arm to rotate. The precision cam is displaced by the torque spring driven by the transmission shaft, and the micro switch is driven to cut off the control line, causing the conveyor to stop running. The installation and adjustment rope switch should be installed in a location with maintenance channels on both sides of the conveyor, and the installation position should ensure that maintenance personnel can operate conveniently in emergency situations. 1. Fix the rope switch on the rack. 2. The distance between the two switches on one side is about 50m, using a diameter ofΦ The steel wire rope connection of 4 should have moderate elasticity. 3. To reduce the impact of the weight of the steel wire rope on the start of the switch, a support ring is installed on the frame every 3 meters to support the steel wire rope. 4. The other end of the steel wire rope is tied to the tension spring (fixed with a rope buckle), and the tension on both sides of the rope is tightened using a tightener without affecting normal use, ensuring that the tension on both sides is balanced. (Note: For the climbing section conveyor, the switch spacing and rope length should be minimized as much as possible.) Precautions: 1. Cut off the main power supply first, and then use a multimeter to measure the live wire. The switch must be installed at one end of the live wire. 2. Cut the live wire in a suitable place, and there are two joints, and the pull switch also has two joints. 3. Peel off the two joints of the live wire and expose the metal wire, and connect them to either of the two joints of the switch. 4. Cut off the excessively long metal wire at the connected joint to prevent two metal wires from colliding and short circuiting. 5. Loosen the cover of the pull switch and you can see a metal shaft with a hole at one end. 6. There is also a hole on the side of the plastic casing of the pull switch. First, pass the pull wire through the opening of the plastic casing to introduce the pull wire into the pull switch. Then, insert one end of the introduced pull wire into the shaft and tie a knot. Shorten the excessively long pull wire after tying. 7. Rotate the cover of the cable switch to prevent electric shock. LJG5C-4/Z2CN2 , LJG5C-4/Z2BN2 , LJG5C-4/Z2CP2 , LJG5C-4/Z2BP2 , LJG5C-4/Z0AN2 LJG5C-4/Z0BN2 , LJG5C-5/Z2CN2 , LJG5C-5/Z2BN2 , LJG5C-5/Z2CP2, LJG5C-5/Z2BP2   LJG5C-5/Z0AN2 , LJG5C-5/Z0BN2 , LU3-10N1, LU3-10N2 , LU3-10P1, LU3-10P2,LU4-16N1 ,     LU4-16N2, LU4-16P1, LU4-16P2, LU4-16D1, LU4-16D2,LU5-16N1, LU5-16N2, LU5-16P1    LU5-16P2, LU5-16D1, LU5-16D2, JKS-J-D,LU5-15N1,LU5-15N2, LU5-15P1,LU5-15P2   LU5-15D1, LU5-15D2, JKD-J-D12,SK-3015A,SK-3015B,SK-3015AB, SK-3015C,SK-3015D SK-3015CD, SK-3015AL, SK-3015BL,SK-2015A,SK-2015B,SJ-3018A,SJ-3018B, SJ-3018AB, SJ-3018C,SJ-3018D,SJ-3018CD,SJ-3018AL,SJ-3018BL,SJ-2018A,SJ-2018B,SD-3020A,SD-3020B,SD-3020AB,SD-3020C,SD-3020D,SD-3020CD,SD-3020AL,SD-3020BL,SD-2020A,SD-2020B, SD-2020AB SE-3025A SE-3025B SE-3025AB&nbp; SE-3025C SE-3025D, SE-3025CD&nbp; SE-3025AL, SE-3025BL, SE-2025A, SE-2025B, SE-2025AB, TCO-3040A, TCO-3040B TCO-3040AB, TCO-3040C, TCO-3040CD, TCO-3040AL, TCO-3040BL, TCO-2040A TCO-2040B, TCO-2040AB, TCA-3050A, TCA-3050B, TCA-3050AB, TCA-3050C, TCA-3050D, TCA-3050CD, TCA-3050AL, TCA-3050BL, TCA-2050A, TCA-2050B, TCA-2050AB, TCB-3080AB, TCB-3080AB, TCB-3080C, TCB-3080D, TCB-3080CD, TCB-3080AL, TCB-3080BL, TCB-2080A, TCB-2080B, TCB-2080AB, TCC-30120A, TCC-30120B, TCC-30120AB, TCC-30120AB 20C, TCC-30120D, TCC-30120CD, TCC-30120AL, TCC-30120BL, TCC-20120A, TCC-20120B, TCC-20120AB,
Capacitive proximity switch LJC12A3-A-Z/AX, LJC12A3-A-Z/BY, LJC12A3-A-Z/AY ,LJC18A3-5-Z/BX, LJC18A3-5-Z/AX LJC18A3-5-Z/BY, LJC18A3-5-Z/AY ,LJC18A3-B-Z/BX , LJC18A3-B-Z/AX, LJC18A3-B-Z/BY LJC18A3-B-Z/AY,LJC24A3-8-Z/BX, LJC24A3-8-Z/AX , LJC24A3-8-Z/BY , LJC24A3-8-Z/AY LJC24A3-8-J/EZ, LJC24A3-8-J/DZ , LJC18A3-B-J/DZ, LJC18A3-5-J/DZ, LJC18A3-5-J/EZ LJC18A3-B-J/EZ,LJC24A3-T-Z/BX, LJC24A3-T-Z/AX, LJC24A3-T-Z/BY , LJC24A3-T-Z/AY LJC24A3-T-J/EZ,LJC24A3-T-J/DZ ,LJC30A3-10-Z/BX, LJC30A3-10-Z/AX ,LJC30A3-10-Z/BY LJC30A3-10-Z/AYLJC30A3-10-J/EZ LJC30A3-10-J/DZ, LJC30A3-H-Z/BX LJC30A3-H-Z/AX LJC30A3-H-Z/BY LJC30A3-H-Z/AY LJC30A3-H-J/EZ LJC30A3-H-J/DZ LJC34A3-K-Z/BX LJC34A3-K-Z/AX LJC34A3-K-Z/BY LJC34A3-K-Z/AY LJC34A3-K-J/EZ LJC34A3-K-J/DZ LJC20A4-10-Z/BXLJC20A4-10-Z/AX LJC20A4-10-Z/BY LJC20A4-10-Z/AY LJC20A4-10-J/EZ LJC20A4-10-J/DZLJC38A4-20-Z/BX LJC38A4-20-Z/AXLJC38A4-20-Z/BY LJC38A4-20-Z/AY LJC38A4-20-J/EZ LJC38A4-20-J/DZLJC80A4-40-Z/BX LJC80A4-40-Z/AXLJC80A4-40-Z/BY LJC80A4-40-Z/AY LJC80A4-40-J/EZ LJC80A4-40-J/DZ LJC12A3-2-Z/BX, LJC12A3-2-Z/AX, LJC12A3-2-Z/BY ,LJC12A3-2-Z/AY, LJC12A3-A-Z/BX

Tags

Get the latest price? We'll respond as soon as possible(within 12 hours)
主站蜘蛛池模板: 亚洲日本天堂在线 | A片A三女人久久7777 | 精品免费久久久久国产一区 | 羞羞的视频在线免费观看 | 欧美日剧在线免费 | 久草视频免费在线看 | 亚洲性在线观看 | 成人免费网站www网站高清 | 日韩欧美在线一区 | 男女下面一进一出无遮挡着 | 日本无码少妇波多野结衣 | 欧美最黄视频 | 国内精品久久久久久99蜜桃 | 222奇米影视| 亚洲天天看| 成年女人免费v片 | 任你干在线视频 | 日产一一到六区麻豆 | 91伊人久久大香线蕉 | 国产亚洲精品久久久久久久软件 | 成人午夜亚洲影视在线观看 | 91青青青国产在观免费影视 | 国产成人一区二区三区 | 国产精品久久久久免费 | 欧美成视频在线观看 | 久草在线播放 | 91精品国产综合久久福利软件 | 香港三级日本三级a视频 | 午夜成人在线视频 | 香港三级日本三级韩国三级韩 | 午夜视频在线看 | 亚洲第一成网站 | 亚洲一级毛片中文字幕 | 天天干天天舔天天操 | 欧美高清国产 | 国产精品99爱免费视频 | 中文字幕在线播放 | 男人的天堂在线视频 | 国内精品免费一区二区三区 | 精品国偷自产在线 | 日本黄色大片免费观看 |